Sign In | Join Free | My burrillandco.com
Home > Drug Abuse Test Kit >

Urine Specimen Drug Abuse Test Kit , 5 Panel Drug Test Kit Gold Colloidal With CE

    Buy cheap Urine Specimen Drug Abuse Test Kit , 5 Panel Drug Test Kit Gold Colloidal With CE from wholesalers
     
    Buy cheap Urine Specimen Drug Abuse Test Kit , 5 Panel Drug Test Kit Gold Colloidal With CE from wholesalers
    • Buy cheap Urine Specimen Drug Abuse Test Kit , 5 Panel Drug Test Kit Gold Colloidal With CE from wholesalers
    • Buy cheap Urine Specimen Drug Abuse Test Kit , 5 Panel Drug Test Kit Gold Colloidal With CE from wholesalers
    • Buy cheap Urine Specimen Drug Abuse Test Kit , 5 Panel Drug Test Kit Gold Colloidal With CE from wholesalers
    • Buy cheap Urine Specimen Drug Abuse Test Kit , 5 Panel Drug Test Kit Gold Colloidal With CE from wholesalers

    Urine Specimen Drug Abuse Test Kit , 5 Panel Drug Test Kit Gold Colloidal With CE

    Ask Lasest Price
    Brand Name : New Life
    Model Number : Panel
    Certification : ISO13485, CE
    Price : USD0.5-USD5
    Payment Terms : T/T, Western Union
    Supply Ability : 2000000pcs/month
    Delivery Time : 20-30days
    • Product Details
    • Company Profile

    Urine Specimen Drug Abuse Test Kit , 5 Panel Drug Test Kit Gold Colloidal With CE

    MultiDrug of Abuse Rapid test,Urine Specimen, High Accuracy, Easily & Quick operation on spot, Gold colloidal method


    Intended Use


    The Multi-Drug Rapid Test Panel with Adulteration is a rapid chromatographic immunoassay for the detection of drugs and drug metabolites in urine at the following cut-off concentrations in urine:


    ProductCat NoSpecimenSensitivityFormatKit Size
    Drugs of Abuse (DOA) Tests
    AMPYD101S3Urine1000 ng/mL3mm Strip100T
    YD101C44mm Cassette25T
    BARYD201S3Urine300 ng/mL3mm Strip100T
    YD201C44mm Cassette25T
    BZOYD301S3Urine300 ng/mL3mm Strip100T
    YD301C44mm Cassette25T
    COCYD401S3Urine300 ng/mL3mm Strip100T
    YD401C44mm Cassette25T
    MOR(MOP)YD501S3Urine300 ng/mL3mm Strip100T
    YD501C44mm Cassette25T
    METYD601SMUrine500 ng/mL3mm Strip100T
    YD601CM4mm Cassette25T
    MTDYD701S3Urine300 ng/mL3mm Strip100T
    YD701C44mm Cassette25T
    MDMAYD801S3Urine500 ng/mL3mm Strip100T
    YD801C44mm Cassette25T
    THCYD901S3Urine50 ng/mL3mm Strip100T
    YD901C44mm Cassette25T
    BUPYD111S3Urine100 ng/mL3mm Strip100T
    YD111C44mm Cassette25T
    PCPYD121S3Urine25 ng/mL3mm Strip100T
    YD121C44mm Cassette25T
    K2YD131S3Urine200 ng/mL3mm Strip100T
    YD131C44mm Cassette25T
    OPIYD141S3Urine2000 ng/mL3mm Strip100T
    YD141C44mm Cassette25T
    TCAYD151S3Urine1000 ng/mL3mm Strip100T
    YD151C44mm Cassette25T
    KETYD161S3Urine1000 ng/mL3mm Strip100T
    YD161C44mm Cassette25T
    TMLYD171S3Urine100 ng/mL3mm Strip100T
    YD171C44mm Cassette25T
    DOA 2-in-1YD021C5UrineSee Insert2-in-1 Panel25T
    DOA 3-in-1YD031C5UrineSee Insert3-in-1 Panel25T
    DOA 4-in-1YD041C5UrineSee Insert4-in-1 Panel25T
    DOA 5-in-1YD051C5UrineSee Insert5-in-1 Panel25T
    DOA 6-in-1YD061C5UrineSee Insert6-in-1 Panel25T
    DOA 7-in-1YD071C5UrineSee Insert7-in-1Panel25T
    DOA 8-in-1YD081C5UrineSee Insert8-in-1Panel25T
    DOA 9-in-1YD091C5UrineSee Insert9-in-1 Panel25T
    DOA 10-in-1YD011C5UrineSee Insert10-in-1 Panel25T
    AlcoholYD151C5SalivaSee InsertStrip100T

    DIRECTIONS FOR USE


    Allow the test, urine specimen, and/or controls to reach room temperature

    (15-30ºC) prior to testing.

    Bring the pouch to room temperature before opening it. Remove the test panel from the sealed pouch and use it within one hour.

    Remove the cap.

    With the arrow pointing toward the urine specimen, immerse the test panel vertically in the urine specimen for at least 10 to 15 seconds. Immerse the dipstick to at least the level of the wavy lines, but not above the arrow on the test panel.

    Replace the cap and place the test panel on a non-absorbent flat surface.

    Start the timer and wait for the colored line(s) to appear.

    The result should be read at 5 minutes. Results may be stable up to 1 hour after test initiation.



    INTERPRETATION OF RESULTS


    (Please refer to the illustration above)

    NEGATIVE:* A colored line appears in the Control region (C) and colored lines appears in the Test region (T). This negative result means that the concentrations in the urine sample are below the designated cut-off levels for a particular drug tested.

    *NOTE: The shade of the colored lines(s) in the Test region (T) may vary. The result should be considered negative whenever there is even a faint line.

    POSITIVE: A colored line appears in the Control region (C) and NO line appears in the Test region (T). The positive result means that the drug concentration in the urine sample is greater than the designated cut-off for a specific drug.

    INVALID: No line appears in the Control region (C). Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for Control line failure. Read the directions again and repeat the test with a new test card. If the result is still invalid, contact your manufacturer.


    QUALITY CONTROL


    A procedural control is included in the test. A line appearing in the control region

    (C) is considered an internal procedural control. It confirms sufficient specimen volume, adequate membrane wicking and correct procedural technique.

    Control standards are not supplied with this kit. However, it is recommended that positive and negative controls be tested as good laboratory practice to confirm the test procedure and to verify proper test performance.


    ORIENT NEW LIFE MEDICAL CO., LTD.
    Contact:Jerry Meng
    Email:Jerry @ newlifebiotest .com
    Tel.+86 18657312116
    SKYPEenetjerry
    Quality Urine Specimen Drug Abuse Test Kit , 5 Panel Drug Test Kit Gold Colloidal With CE for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Orient New Life Medical Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)